CPI300D - Differential Input Process Indicator

Print

 

Overview

CPI 300D instruments are Dual Channel Differential Reading instruments. CPI 300D measure and display process parameters like level, Pressure, Temperature, Flow, Vibration, Humidity, Wind Speed and more. These instruments accept a voltage or current input and convert them to the programmed process variable Settings are saved in non-volatile memory and no battery backup is required. The user can program two independent display modes. Typical applications include Level and Volume display in the same instrument. These instruments also have the capability to switch on relay(s) based on user settings. These outputs can be used for process set points and alarms, and for controlling pumps. These instruments are panel mount Optional features includes: RS485 / MODBUS network protocol, Upto 2 relays can be programmed using 4 setpoints and current output of 4-20mA.

Feature

16 Character 2 Line Backlit LCD Display
4-20 mA or 0-20 mA current input, 0-5VDC or 0-
  10VDC Voltage Input
Dual Channel Differential Reading
2 Wire / 3 Wire Compatible
Linear, Square root, Lookup table conversion
0.05 % Accuracy
2 Programmable Indicating modes
4 Programmable Setpoints operating 2 relays
RS485 / MODBUS Network
Upto 250mA Instrument Powersupply
Panel Mount Enclosure (96 X 96 X 110)
4-20mA Current output

Specification
Power supply : 220 VAC ± 10 %, 12 – 24 VDC (Factory settable only)
Power : 1 Watt maximum
Indication : 16 Character 2 Line Backlit LCD ( Displays the two channels input and also displays difference
    between those two channels)
No of Channels : 2
Signal Type : 4-20mA
Signal Maximum : Protected for 40mA continuous
Output Power : 24V DC Regulated at 250 mA maximum (no fuse provided)
Relay output : 1
Zero and Span : -19999 to 19999
Conversion Type : Linear, Square root, Lookup table (16 points max.)
Operating Temperature : -0 – 50 °C
Storage Temperature : 0 – 60 °C
Humidity : 0 – 80 non condensing
Accuracy : ± 1 Count over a conversion range of 0 – 8192 counts
Program Variables : Saved in non-volatile EEPROM. No battery backup necessary. Data retention 100 years
    maximum
Programming Method : From keypad provided in the instrument
Housing : Field mount, Panel mount (96 X 96 X 110)
OPTIONAL:  
Signal Type : 0-20mA (or) 0-5VDC (or) 0-10VDC (Factory settable only)
Output Power : 12V DC Regulated at 250 mA maximum (no fuse provided)
Relay output : 2
Communication : RS-485 (MODBUS)
Current output : 4-20mA