CWD 100 - Computerised Water Dispenser
Specification
Power supply : 220 VAC ± 10 %, 12 – 24 VDC (Factory settable only)
Power Consumption : 1 Watt maximum
Indication : CFI 100 Series: 16 Character 2 Line Backlit LCD display
No of Channels : 1
Signal Maximum : Reed Switch input: No potential on the inputs Open Collector input: Restricted to
12V maximum output from the unit TTL Input: Restricted to 5V input from sensor
Pulse Frequency : 0 to 4Khz Maximum
Pulse Amplitude Protection : Protected up to 14 V Maximum Amplitude continuous
Output Power : 5V /12V DC Regulated at 750 mA peak maximum (no fuse provided) Factory
    settable
Sensor Supply Regulation: : 10 %
Zero and Span : NA
Conversion Type : Pulse Totalization
Operating Temperature : 0 – 50 °C
Storage Temperature : 0 – 60 °C
Humidity : 0 – 80 non condensing
Program Variables : Saved in non-volatile EEPROM. No battery backup necessary. Data retention 100
years maximum
Programming Method : From keypad provided in the instrument
Housing : Panel mount 96mm x 96mm x 110mm