CFI100 - Flow Indicator w/ Pulse I/P

Print

 

 

Overview

CFI100 series flow meters are extremely versatile flow indicators that can be used with a variety of pulse output flow sensors. These indicators offer extreme reliability and low cost for flow measurement. CFI100 series flow indicators can be used with mV pulse output sensors, open collector pulse output sensors as well as TTL pulse output sensors. Microcontroller based electronics ensures accurate readings for both rate of flow indication and total flow indication. A number of programmable features including In-line calibration are standard. All the parameters are saved in a non volatile EEPROM memory which doesn't needs any external battery. There is a advanced power fail feature by which even if there is any power failure the Total Flow reading is automatically saved to memory and resumes with the same value after Power On. Advanced models can offer relay outputs for signals exceeding rate of flow or total flow set points. Programmable pulse output models are also available in addition to the industry standard 4-20mA output. These instruments can be connected to a PC via RS485/ RS 232 using MODBUS interface.

Feature

+-1 % of full scale Accuracy
Rate of Flow, Total Flow
Microcontroller signal processing
16 Chr. 2 Line Backlit LCD Display
Programmable Relay Outputs
Batch Mode Operation
Variety of Sensor Fittings
RS232/RS485 - MODBUS CommunicationEnclosure
Panel Mount, Table Top
Field Programmable through four keys
Compact Size
Reed Switch input / Paddle wheel input

 

Specification
Input : Pulse, 4-20mA / 0-20mA / 0-2.5V / 0-5V
    Factory settable
Number of Channels : 1 (2 for Differential Indicators)
Indication : 16 Character 2 Line Backlit LDD Display
Indication Modes : 5 Digit ½” LED Display
Voltage Drop : 2.5V Maximum (Applicable only for current input models)
Input Impedance : 10K Ohms (Applicable only for voltage input models)
Resolution : 13 bits (8192 counts)
Accuracy at 25 Deg C : 0.1% of span +- 1 count
Temperature Variations : 1 Count per 10 Deg C max.
Operating Temperature : 0 to 50 Deg Cel
Storage Temperature : -40 to 85 Deg C
Conversion Modes : Linear, Square Root, Lookup Table (User
    Selectable)
Relay Output : 1 Standard, 2 Optional
Power Requirement
Voltage : 220VAC +-15% or 8 to 24VAC/DC (Factory
    Settable)
Frequency : 50/60 Hz
Power Consuption : Less than 1 Watt
Optional Features
Sensor Supply : SMPS upto 1A at 24V DC
Network Capability : RS485, MODBUS protocol
Direct Printer Interface : Prints Time, Total Flow at programmed intervals